穩壓(ya)(ya)器(qi)是使(shi)輸(shu)出(chu)電壓(ya)(ya)穩定的設備。穩壓(ya)(ya)器(qi)由調(diao)壓(ya)(ya)電路、控制電路、及伺服電機(ji)等組成(cheng)。當輸(shu)入電壓(ya)(ya)或負載變化時,控制電路進行(xing)取樣(yang)、比較、放(fang)大(da),然后驅動(dong)伺服電機(ji)轉動(dong),使(shi)調(diao)壓(ya)(ya)器(qi)碳刷的位(wei)置(zhi)改變,通過自(zi)動(dong)調(diao)整(zheng)線圈匝數(shu)比,從而(er)保持輸(shu)出(chu)電壓(ya)(ya)的穩定。
穩(wen)壓(ya)器(qi)是一種能自動調整輸(shu)出(chu)電(dian)(dian)(dian)(dian)壓(ya)的供(gong)電(dian)(dian)(dian)(dian)電(dian)(dian)(dian)(dian)路(lu)或供(gong)電(dian)(dian)(dian)(dian)設備,其作(zuo)用是將波動較(jiao)大和(he)達不到電(dian)(dian)(dian)(dian)器(qi)設備要求的電(dian)(dian)(dian)(dian)源電(dian)(dian)(dian)(dian)壓(ya)穩(wen)定在(zai)它的設定值(zhi)范圍內,使各種電(dian)(dian)(dian)(dian)路(lu)或電(dian)(dian)(dian)(dian)器(qi)設備能在(zai)額定工(gong)作(zuo)電(dian)(dian)(dian)(dian)壓(ya)下正常工(gong)作(zuo)。
最(zui)初的(de)(de)電(dian)力穩(wen)(wen)壓器是靠繼電(dian)器的(de)(de)跳動(dong)穩(wen)(wen)定(ding)電(dian)壓的(de)(de)。當電(dian)網電(dian)壓出現波動(dong)時(shi),電(dian)力穩(wen)(wen)壓器的(de)(de)自動(dong)糾正電(dian)路啟動(dong),使(shi)(shi)(shi)內(nei)部繼電(dian)器動(dong)作。迫使(shi)(shi)(shi)輸出電(dian)壓保(bao)持在設(she)定(ding)值附近,這種電(dian)路優點是電(dian)路簡(jian)單,缺點是穩(wen)(wen)壓精度不高并(bing)且(qie)每(mei)一次繼電(dian)器跳動(dong)換擋,都(dou)會使(shi)(shi)(shi)供(gong)電(dian)電(dian)源發生一次瞬時(shi)的(de)(de)中(zhong)斷并(bing)產(chan)生火花干擾。
這對(dui)電腦設備的讀寫工作干擾很大,容(rong)易造成電腦出現錯誤(wu)信號(hao),嚴重(zhong)時還會(hui)使硬盤(pan)損壞。
高(gao)質(zhi)量的(de)小型穩壓(ya)器(qi),大多采(cai)用電(dian)機(ji)拖(tuo)動碳刷的(de)方法穩定電(dian)壓(ya),這種穩壓(ya)器(qi)對電(dian)器(qi)設(she)備產生(sheng)的(de)干擾很小穩壓(ya)精度相對較高(gao)。
【詳細>>】
由于部分電器中含有線圈(quan)組件,在通電(dian)初(chu)期會產(chan)(chan)生阻礙電(dian)流(liu)的(de)渦流(liu),渦流(liu)的(de)產(chan)(chan)生既(ji)會削弱到電(dian)器啟動時(shi)的(de)瞬時(shi)電(dian)壓(ya),導致(zhi)啟動緩慢,又會加強斷路后產(chan)(chan)生的(de)瞬時(shi)電(dian)壓(ya),可(ke)能產(chan)(chan)生火花損壞電(dian)路。此時(shi)便需(xu)要一個穩壓(ya)器來保護電(dian)路的(de)正常(chang)運行。
穩壓器由調壓電路、控制電路、及伺服電機等組成,當輸入電壓或負載變化時,控制電路進行取樣、比較、放大,然后驅動伺服電機轉動,使調壓器碳刷的位置改變,通過自動調整線圈匝數比,從而保持輸出電壓的穩定。容量較大的穩壓器,還采用電壓補償的原理工作。【詳細>>】
1、穩(wen)壓器所標輸出(chu)功(gong)率是最大功(gong)(gong)(gong)率(lv)(lv)(lv)。家用電器的標稱功(gong)(gong)(gong)率(lv)(lv)(lv)是(shi)指(zhi)有功(gong)(gong)(gong)功(gong)(gong)(gong)率(lv)(lv)(lv),而冰箱、空調、水(shui)泵等(deng)感性負載在啟動瞬時(shi)間電流(liu)很大,因此電冰箱、空調、水(shui)泵按(an)功(gong)(gong)(gong)率(lv)(lv)(lv)×(3~5倍)。
例如:3匹美的空調(220V用(yong)電)
1匹等于0.75千瓦×3匹=2.25千瓦×3倍(bei)感性負載啟(qi)動電流(liu)=6.75千瓦(wa)以上(shang)穩(wen)(wen)壓(ya)器(qi)適用。(美的維修(xiu)裝技師推薦選(xuan)用8KVA穩(wen)(wen)壓(ya)器(qi))
2、以專業水電安裝技師及工廠專業電工、工程(cheng)師和穩壓(ya)器使用(yong)(yong)功(gong)(gong)率(lv)(lv)算法:一般(ban)工業設(she)備按額定功(gong)(gong)率(lv)(lv)至(zhi)少(shao)乘以2倍以上使用(yong)(yong)功(gong)(gong)率(lv)(lv),當使用(yong)(yong)在具備電機(ji)運(yun)轉設(she)備、大電流啟(qi)動(dong)裝置及(ji)沖擊性負載設備上(shang)時,應(ying)選擇3倍以上(shang)容量的穩壓(ya)器,以免(mian)啟動(dong)電流過大(da),供電線路降壓(ya)而無(wu)法正(zheng)常工作。
如:某一工廠的汽泵機(380V用電設備)某電機(ji)功(gong)率(lv)為(wei)7.5千(qian)瓦,然而它(ta)開(kai)始(shi)運轉沖擊作功(gong)時(shi)浪涌電流過(guo)到電機(ji)功(gong)率(lv)的(de)3倍(bei)以(yi)上,所以(yi)必須(xu)選擇大于其功(gong)率(lv)3倍(bei)的(de)穩壓(ya)器(qi)。
3、0.5KVA—3KVA穩壓(ya)器選擇輸出電壓(ya)110V時,則輸入容量不能超過額定容量的40%,當輸出端需110V和220V同時使用時輸出容量應在額定容量的50%,以免過載。【詳細>>】
購買(mai)穩(wen)(wen)壓(ya)器(qi)(qi)時,建議大(da)家至少要選(xuan)購比實(shi)際功率大(da)三倍(bei)的穩(wen)(wen)壓(ya)器(qi)(qi),因(yin)為穩(wen)(wen)壓(ya)器(qi)(qi)在(zai)實(shi)際工作(zuo)中要克服市電的浪涌沖擊和(he)感性負載的起動(dong)沖擊(如(ru)冰(bing)箱、空調、馬達和(he)電動(dong)機)。
1、穩(wen)(wen)壓(ya)器(qi)用在感性(xing)負(fu)載(zai)時(shi)(shi)(shi)(shi),由于(yu)感性(xing)負(fu)載(zai)有較大(da)的(de)瞬間(jian)起動電(dian)流(liu),一般約為額定電(dian)流(liu)的(de)3—5倍(bei)往往超過運(yun)行(xing)電(dian)流(liu)的(de)9倍(bei)(如電(dian)冰箱、空(kong)調器(qi)、洗衣機(ji)(ji)、電(dian)扇、大(da)型空(kong)調,印(yin)刷機(ji)(ji),空(kong)壓(ya)機(ji)(ji),電(dian)梯,水泵等(deng)都屬于(yu)感性(xing)負(fu)載(zai)),所以(yi)凡配用電(dian)動機(ji)(ji)、壓(ya)縮機(ji)(ji)電(dian)器(qi)等(deng)感性(xing)負(fu)載(zai)的(de)穩(wen)(wen)壓(ya)器(qi),都必須考(kao)慮其(qi)功率儲備,要留有余量(liang),就(jiu)要預留足夠的(de)余量(liang),避免負(fu)載(zai)開機(ji)(ji)時(shi)(shi)(shi)(shi)產生的(de)沖擊電(dian)流(liu)對(dui)穩(wen)(wen)壓(ya)器(qi)造成(cheng)即(ji)時(shi)(shi)(shi)(shi)的(de)損害。如整廠使用穩(wen)(wen)壓(ya)器(qi),在啟動機(ji)(ji)器(qi)時(shi)(shi)(shi)(shi),應避免大(da)功率感性(xing)負(fu)載(zai)同一時(shi)(shi)(shi)(shi)間(jian)啟動,所以(yi)在選購穩(wen)(wen)壓(ya)器(qi)時(shi)(shi)(shi)(shi),應有1.5倍(bei)的(de)預留容量(liang)單機(ji)(ji)配套的(de)預留量(liang)應有3倍(bei)。
2、注意市(shi)電(dian)供電(dian)的(de)電(dian)壓(ya)值(zhi),是否超出(chu)所選購(gou)的(de)穩壓(ya)器規定的(de)輸(shu)入(ru)電(dian)壓(ya)范圍,三相電(dian)電(dian)壓(ya)有否相差10V以(yi)上
3、在購機前,要考慮日后(hou)業務擴(kuo)展,是否需要增加設備,穩壓器是否需要預(yu)留擴(kuo)展容(rong)量
4、無論是單機配套或整廠配套,選購的(de)(de)穩(wen)壓(ya)器(qi)(qi)要預留(liu)一定的(de)(de)預留(liu)容量,避(bi)免(mian)穩(wen)壓(ya)器(qi)(qi)百(bai)分百(bai)的(de)(de)負載(zai)率,穩(wen)壓(ya)器(qi)(qi)的(de)(de)負載(zai)率一般(ban)達90%這樣較為(wei)適(shi)宜。自動調壓(ya)器(qi)(qi)的(de)(de)外形結構有臺式(shi)、掛壁式(shi)、臺壁兩(liang)用式(shi)和落地式(shi)等(deng)幾種,應根據安裝放置的(de)(de)位置、主(zhu)要用途,以(yi)及安裝能力,選擇不同的(de)(de)款式(shi)。
5、業內人士提示,在選擇穩壓器時,還要注意要選擇品牌知名度高的產品,因為這些廠家質量可靠、服務周到;同時廠家是否有良好的售后服務,如產品質量執行三包等,也是消費者應注意的重要因素。【詳細>>】
1、接(jie)入市電(按照(zhao)國家規定的左零右火接(jie)線標準)
①接入(ru)設備的(de)輸入(ru)導線(xian)(xian)線(xian)(xian)徑必(bi)須保證≥25mm2銅芯線(xian)(xian)
②接入設備的(de)輸(shu)入,輸(shu)出(chu)線卡鏍絲必須(xu)擰(ning)緊
③輸入、輸出線不得接反
④設備前端不能以漏電保護器代替(ti)空氣開關(guan)
2、接入負載
負載(zai)(zai)功率(lv)不(bu)能(neng)超出(chu)穩壓電(dian)源的最大功率(lv):例:50KVA.一(yi)般負載(zai)(zai)率(lv)為50KVA×0.8=40KW
①輸出線路的所有線接口必須接緊(jin),否則會因(yin)為電流較(jiao)大造成線路發熱,來(lai)影響有效功率。
3、開啟(qi)穩壓(ya)電(dian)源(嚴禁(jin)先開啟(qi)負載,后開啟(qi)穩壓(ya)電(dian)源)
①請保證電(dian)(dian)腦(nao)顯(xian)示(shi)器是關(guan)閉的情(qing)況(kuang)下(xia)開啟穩壓電(dian)(dian)源。
②開啟(qi)之(zhi)前先測量輸(shu)入電壓值應在(zai)304V-456V之(zhi)間(jian)。
③察看機器自(zi)帶的(de)輸出(chu)電壓表應為380V。
4、不要使(shi)用過高的負載;
5、請使(shi)用足夠的電線;
6、請小心連接好(hao)輸入電壓和儀器設備(bei)的輸出;
7、儀器設備與穩壓(ya)器的輸出電壓(ya)要統一;
8、請選擇好輸入電壓(ya)開關與(yu)電源電壓(ya)一樣;
9、如果保險絲燒壞,請核對負載設備(bei);
10、要用(yong)同(tong)一定額的保(bao)險(xian)絲(si),不能使(shi)用(yong)非額定保(bao)險(xian)絲(si)或電(dian)線(xian);
11、安裝在干燥通風的地方。【詳細>>】
穩(wen)壓器是按用(yong)電(dian)設備的要求提供穩(wen)定輸出電(dian)壓的一種設備。主要有智能數控型(xing)、自耦調(diao)整型(xing)、大功率補償型(xing)、開關型(xing)等(deng)種類。
穩壓器(qi)日常保(bao)養要注意4點:
1、穩壓器應放置在通風、干(gan)燥、無陽光(guang)直射、無腐蝕性氣體的室內使用;
2、穩壓器選(xuan)用的(de)功(gong)率應大于用電(dian)設備的(de)總功(gong)率;
3、穩壓器(qi)開關(guan)不宜作設(she)備的(de)總開關(guan)使用(yong),應先打開穩壓器(qi)開關(guan),待有電源輸出后,再依次從(cong)按功率小(xiao)到(dao)大接上不同的(de)用(yong)電設(she)備,關(guan)機時從(cong)大到(dao)小(xiao)關(guan)機,最(zui)后關(guan)上穩壓器(qi)的(de)開關(guan);
4、穩壓(ya)器(qi)的開關不(bu)宜頻繁(fan)開啟(qi),每次開啟(qi)的時(shi)間間隔應大于10秒(miao),否則易造成稱穩壓(ya)器(qi)誤保護,甚(shen)至于損(sun)壞。
第一、電(dian)壓偏高需(xu)降壓;當輸入電(dian)壓遠遠高于穩壓設備(bei)(bei)所承載的額定電(dian)壓,這時就會導致穩壓設備(bei)(bei)失靈,故而出現電(dian)壓不穩;
第二、過(guo)壓保(bao)護(hu)(hu)電路;過(guo)壓保(bao)護(hu)(hu)后,LED發光管亮,從(cong)而出現(xian)斷電現(xian)象(xiang);
第三、欠(qian)壓(ya)保護(hu)電路(lu);電壓(ya)偏低,通過調壓(ya)器(qi)的調整仍不(bu)在范圍內(低于220V),最終導致繼電器(qi)釋放,即便有二極(ji)管此時也(ye)管用了,故而出現電壓(ya)不(bu)穩。
第(di)四(si)、取樣電(dian)壓(ya)與基準(zhun)電(dian)壓(ya);取樣電(dian)壓(ya)和基準(zhun)電(dian)壓(ya)接入(ru)(ru)電(dian)壓(ya)比較器(qi)輸(shu)入(ru)(ru)端的規律(lv)是(shi)(shi):檢測電(dian)腦(nao)穩壓(ya)器(qi)輸(shu)出電(dian)壓(ya)是(shi)(shi)否高于額定(ding)值220V,其正輸(shu)入(ru)(ru)端接取樣電(dian)壓(ya),負輸(shu)入(ru)(ru)端接基準(zhun)電(dian)壓(ya)。
第五、電(dian)壓(ya)偏低(di)需(xu)要升壓(ya);若因(yin)輸入電(dian)壓(ya)偏高或(huo)偏低(di)較多,電(dian)動機拖動碳(tan)(tan)刷(shua)轉(zhuan)至極限位置仍不能使(shi)輸出電(dian)壓(ya)回(hui)到220V,碳(tan)(tan)刷(shua)架(jia)將觸(chu)及限位開關(guan),電(dian)動機斷電(dian)停轉(zhuan),以(yi)免電(dian)動機過載損壞。
第六、開(kai)(kai)機延(yan)時(shi)(shi)間斷控(kong)制;到開(kai)(kai)機延(yan)時(shi)(shi)結束。這個過程大約需(xu)要(yao)5分鐘(zhong)。開(kai)(kai)機延(yan)時(shi)(shi)送(song)電(dian)主要(yao)是為(wei)(wei)了保護空調、電(dian)冰箱等設備的用電(dian)安全,若無此(ci)需(xu)求(qiu),可按下快啟自鎖(suo)按鈕AN,此(ci)時(shi)(shi)開(kai)(kai)機延(yan)時(shi)(shi)時(shi)(shi)間將縮短為(wei)(wei)2~3秒鐘(zhong),開(kai)(kai)機延(yan)時(shi)(shi)送(song)電(dian)主要(yao)是為(wei)(wei)了保護電(dian)路的用電(dian)安全;