燃氣緊急切斷閥的工作原理
1、直動式燃氣電磁閥原理
直動式(shi)燃(ran)氣電(dian)(dian)(dian)磁閥(fa)(fa)(fa)是通(tong)過電(dian)(dian)(dian)磁力把封閉件從(cong)閥(fa)(fa)(fa)座上提起或關(guan)閉的,當電(dian)(dian)(dian)磁閥(fa)(fa)(fa)線圈(quan)得電(dian)(dian)(dian)時,電(dian)(dian)(dian)磁閥(fa)(fa)(fa)打開(kai)(kai)(kai),此(ci)時磁性開(kai)(kai)(kai)關(guan)輸(shu)(shu)入源(yuan)與(yu)輸(shu)(shu)出(chu)開(kai)(kai)(kai)觸(chu)(chu)點(dian)接觸(chu)(chu),輸(shu)(shu)入源(yuan)與(yu)輸(shu)(shu)出(chu)關(guan)觸(chu)(chu)點(dian)斷開(kai)(kai)(kai),線圈(quan)保持通(tong)電(dian)(dian)(dian)電(dian)(dian)(dian)磁閥(fa)(fa)(fa)處(chu)于開(kai)(kai)(kai)啟(qi)狀(zhuang)態(tai)。當電(dian)(dian)(dian)磁閥(fa)(fa)(fa)線圈(quan)失電(dian)(dian)(dian)時,電(dian)(dian)(dian)磁閥(fa)(fa)(fa)迅速關(guan)閉,此(ci)時磁性開(kai)(kai)(kai)關(guan)輸(shu)(shu)入源(yuan)與(yu)輸(shu)(shu)出(chu)關(guan)觸(chu)(chu)點(dian)接通(tong),輸(shu)(shu)入源(yuan)與(yu)輸(shu)(shu)出(chu)關(guan)觸(chu)(chu)點(dian)斷開(kai)(kai)(kai)。
2、先導式燃氣電磁閥原理
先導式燃(ran)氣(qi)電磁閥(fa)通(tong)電時,上腔室壓(ya)(ya)力敏捷(jie)降落,封(feng)(feng)閉(bi)(bi)件四周形成上低下(xia)(xia)高(gao)的壓(ya)(ya)差,流(liu)體壓(ya)(ya)力推(tui)動封(feng)(feng)閉(bi)(bi)件向上移動,閥(fa)門打開。斷電時,彈(dan)簧(huang)力把先導孔(kong)(kong)封(feng)(feng)閉(bi)(bi),進口壓(ya)(ya)力通(tong)過旁(pang)通(tong)孔(kong)(kong)敏捷(jie)腔室,在(zai)關閥(fa)件四周形成下(xia)(xia)低上高(gao)的壓(ya)(ya)差,流(liu)體壓(ya)(ya)力推(tui)動封(feng)(feng)閉(bi)(bi)件向下(xia)(xia)移動,封(feng)(feng)閉(bi)(bi)閥(fa)門。
3、散布直動燃氣電磁閥原理
散布(bu)直動(dong)(dong)(dong)燃氣電(dian)磁閥(fa)采(cai)用(yong)直動(dong)(dong)(dong)和(he)先(xian)導(dao)式相(xiang)聯合的原理,通(tong)電(dian)后,電(dian)磁力直接把先(xian)導(dao)小閥(fa)和(he)主(zhu)閥(fa)封(feng)閉(bi)件依次向(xiang)上(shang)提起,閥(fa)門打開(kai)(kai)。當進口與出口達到啟動(dong)(dong)(dong)壓(ya)差(cha)(cha)時,通(tong)電(dian)后,電(dian)磁力先(xian)導(dao)小閥(fa),主(zhu)閥(fa)下腔(qiang)壓(ya)力上(shang)升,上(shang)腔(qiang)壓(ya)力降落,從而利用(yong)壓(ya)差(cha)(cha)把主(zhu)閥(fa)向(xiang)上(shang)推開(kai)(kai)。斷電(dian)時,先(xian)導(dao)閥(fa)利用(yong)彈(dan)簧(huang)力或介質壓(ya)力推動(dong)(dong)(dong)封(feng)閉(bi)件,向(xiang)下移動(dong)(dong)(dong),使閥(fa)門封(feng)閉(bi)。
安裝燃氣電磁閥有哪些要求
1、閥門安裝(zhuang)單位應具(ju)備(bei)相應資質,并(bing)按相關(guan)的燃氣管(guan)道施工規范安裝(zhuang)。
2、閥(fa)門應安裝在戶(hu)內的總(zong)進氣閥(fa)之后,以便(bian)檢修。
3、應(ying)按閥(fa)體標明(ming)的氣(qi)流方(fang)向安裝,閥(fa)體線(xian)圈不得(de)倒立,允許水平(ping)和垂直安裝。
4、電磁閥(fa)控(kong)制(zhi)線應正確可(ke)靠(kao)連接,控(kong)制(zhi)線有極性。白色線為(wei)正極黑(hei)色線為(wei)負(fu)極,不能接反。
5、管(guan)道吹掃時,建(jian)議(yi)將(jiang)電(dian)磁閥(fa)隔(ge)離,以免管(guan)內雜物(wu)損壞(huai)閥(fa)門密封(feng)材料。
6、管道在進(jin)行試(shi)壓(ya)檢測密封性能前,應(ying)先使電磁閥處開閥狀態。
7、手動開閥(fa)時,宜在閥(fa)門進(jin)出口(kou)壓力平(ping)衡時操作(zuo)。
8、電動關閥時,切忌接錯電源,如接錯極性、加錯電壓或長時間通電等,以免損壞電磁線圈,導致燃氣泄漏時不能(neng)及時發現(xian)。
申明:以上方法源于程序系統索引或網民分享提供,僅供您參考使用,不代表本網站的研究觀點,證明有效,請注意甄別內容來源的真實性和權威性。