臭氧檢測儀的工作原理
臭(chou)(chou)氧制備(bei)車間(jian)、化(hua)工(gong)、石(shi)油、造紙、紡織、制藥和香(xiang)精香(xiang)料工(gong)業等(deng)都少不了要用到臭(chou)(chou)氧檢測儀,這是采用紫(zi)(zi)(zi)外(wai)(wai)線吸(xi)(xi)收法的原理,用穩(wen)定(ding)的紫(zi)(zi)(zi)外(wai)(wai)燈光(guang)(guang)(guang)(guang)源產生紫(zi)(zi)(zi)外(wai)(wai)線,用光(guang)(guang)(guang)(guang)波(bo)過(guo)濾器(qi)(qi)(qi)過(guo)濾掉(diao)其它波(bo)長紫(zi)(zi)(zi)外(wai)(wai)光(guang)(guang)(guang)(guang),只允(yun)許波(bo)長253.7nm通過(guo)。經(jing)過(guo)樣品光(guang)(guang)(guang)(guang)電(dian)傳感(gan)(gan)器(qi)(qi)(qi),再經(jing)過(guo)臭(chou)(chou)氧吸(xi)(xi)收池后,到達采樣光(guang)(guang)(guang)(guang)電(dian)傳感(gan)(gan)器(qi)(qi)(qi)。通過(guo)樣品光(guang)(guang)(guang)(guang)電(dian)傳感(gan)(gan)器(qi)(qi)(qi)和采樣光(guang)(guang)(guang)(guang)電(dian)傳感(gan)(gan)器(qi)(qi)(qi)電(dian)信號比較,再經(jing)過(guo)數(shu)學模型的計算,就能(neng)得出臭(chou)(chou)氧濃度大(da)小。
臭氧檢測儀的使用方法
1、校正(zheng),校正(zheng)是為了減少檢測誤(wu)差(cha),主要有兩種(zhong)方(fang)法(fa):
(1)校(xiao)(xiao)準(zhun)儀器校(xiao)(xiao)準(zhun),采用(yong)紫外光法臭氧(yang)檢(jian)測儀對已生(sheng)產的臭氧(yang)檢(jian)測儀進(jin)行分(fen)布選(xuan)取10個(ge)測試點對比,誤(wu)差范圍(wei)控制在+1 %以內(nei)為合格。
(2)化學滴(di)(di)定(ding)(ding)法(fa),國際(ji)公認化學方法(fa),即碘化鉀(jia)、硫(liu)代硫(liu)酸鈉滴(di)(di)定(ding)(ding)法(fa)來檢測臭氧濃度。我們(men)也(ye)分布選取(qu)10個(ge)測試點(dian),然后用(yong)臭氧檢測儀與(yu)化學滴(di)(di)定(ding)(ding)法(fa)測試的10個(ge)點(dian)進行對(dui)比,誤差范(fan)圍控(kong)制在 +1%以(yi)內。碘化鉀(jia)滴(di)(di)定(ding)(ding)法(fa)原理是(shi)用(yong)強氧化劑臭氧與(yu)碘化鉀(jia)反應(ying),使碘游離出來到水里,水就會變為(wei)(wei)茶(cha)色(se),再(zai)利用(yong)硫(liu)代硫(liu)酸鈉標準液滴(di)(di)定(ding)(ding),使游離碘變為(wei)(wei)碘化鈉,反應(ying)終點(dian)為(wei)(wei)水完全(quan)褪色(se)。
2、開啟(qi)中央(yang)空調,確認風管有風吹入潔凈空間(jian)。
3、給臭氧發生器通入(ru)冷卻水(shui),確定臭氧出氣口已(yi)用管道導入(ru)中央空調(diao)送風或(huo)回風管道,然后開啟(qi)臭氧發生器,正常開機時(shi)間一般為(wei)1小時(shi)。
4、臭(chou)(chou)氧(yang)(yang)(yang)濃(nong)(nong)度(du)檢(jian)測(ce)儀(yi)的(de)(de)開(kai)機方法是:長按開(kai)關(guan)鍵約5秒(miao)鐘,有顯(xian)示(shi)后放開(kai),暖(nuan)機時(shi)(shi)間(jian)為120秒(miao),過了暖(nuan)機時(shi)(shi)間(jian)就(jiu)可以(yi)檢(jian)測(ce)空氣中的(de)(de)臭(chou)(chou)氧(yang)(yang)(yang)濃(nong)(nong)度(du),臭(chou)(chou)氧(yang)(yang)(yang)濃(nong)(nong)度(du)以(yi)數字(zi)形式顯(xian)示(shi)在檢(jian)測(ce)儀(yi)的(de)(de)顯(xian)示(shi)板上(shang)。臭(chou)(chou)氧(yang)(yang)(yang)濃(nong)(nong)度(du)超過20ppm時(shi)(shi)臭(chou)(chou)氧(yang)(yang)(yang)檢(jian)測(ce)儀(yi)會報警(jing)并閃(shan)光,最大量(liang)程(cheng)是100ppm。
5、一(yi)般建議按時間段進入潔凈區檢(jian)測(ce)臭氧濃度,臭氧發(fa)生器(qi)(qi)工(gong)作30分(fen)鐘(zhong)(zhong)后檢(jian)測(ce)一(yi)次,臭氧發(fa)生器(qi)(qi)工(gong)作60分(fen)鐘(zhong)(zhong)后檢(jian)測(ce)一(yi)次,如有必要則(ze)90分(fen)鐘(zhong)(zhong)及120分(fen)鐘(zhong)(zhong)再(zai)各檢(jian)測(ce)一(yi)次。
一般臭(chou)(chou)(chou)氧(yang)(yang)發生器工作30分鐘后就能馬上檢(jian)測(ce)到臭(chou)(chou)(chou)氧(yang)(yang)濃(nong)(nong)度,工常工作時間為1小時;如(ru)果(guo)(guo)檢(jian)測(ce)不到臭(chou)(chou)(chou)氧(yang)(yang)濃(nong)(nong)度或偏(pian)低則要檢(jian)測(ce)臭(chou)(chou)(chou)氧(yang)(yang)是(shi)否有導(dao)入(ru)管道內或者(zhe)臭(chou)(chou)(chou)氧(yang)(yang)是(shi)否有漏泄;如(ru)果(guo)(guo)臭(chou)(chou)(chou)氧(yang)(yang)有漏泄則會導(dao)致(zhi)臭(chou)(chou)(chou)氧(yang)(yang)濃(nong)(nong)度偏(pian)低;如(ru)果(guo)(guo)檢(jian)測(ce)空氣中臭(chou)(chou)(chou)氧(yang)(yang)濃(nong)(nong)度過(guo)高則控(kong)制好滅(mie)菌的(de)時間即可(ke)。
以上操作就能夠幫助(zhu)我(wo)們測量出(chu)臭(chou)氧的濃度,在操作的過程中一定要細心,避免(mian)出(chu)現誤差,造成結果的錯誤。另外,臭(chou)氧濃度過高(gao)會給人體帶來損害,在使用臭(chou)氧檢(jian)測儀(yi)時需(xu)要注意防(fang)護安(an)全。
申明:以上方法源于程序系統索引或網民分享提供,僅供您參考使用,不代表本網站的研究觀點,證明有效,請注意甄別內容來源的真實性和權威性。