一、三極管測量方法是什么
1、萬用表測量
首(shou)先將(jiang)萬用表(biao)打到測試(shi)二(er)極管(guan)(guan)端,用萬用表(biao)的紅表(biao)筆(bi)接觸三極管(guan)(guan)的其中一(yi)個管(guan)(guan)腳(jiao)(jiao),而用萬用表(biao)另外的那(nei)支表(biao)筆(bi)去測試(shi)其余(yu)的管(guan)(guan)腳(jiao)(jiao),直到測試(shi)出如下結果:
(1)如果(guo)三(san)極管(guan)(guan)(guan)的黑(hei)表(biao)(biao)筆(bi)接其(qi)中(zhong)(zhong)一(yi)個(ge)(ge)管(guan)(guan)(guan)腳(jiao),而用(yong)(yong)紅(hong)表(biao)(biao)筆(bi)測(ce)其(qi)它兩個(ge)(ge)管(guan)(guan)(guan)腳(jiao)都(dou)導通有電壓(ya)顯示(shi),那(nei)么(me)此三(san)極管(guan)(guan)(guan)為PNP三(san)極管(guan)(guan)(guan),且黑(hei)表(biao)(biao)筆(bi)所接的腳(jiao)為三(san)極管(guan)(guan)(guan)的基極B,用(yong)(yong)上述(shu)方法測(ce)試(shi)時其(qi)中(zhong)(zhong)萬用(yong)(yong)表(biao)(biao)的紅(hong)表(biao)(biao)筆(bi)接其(qi)中(zhong)(zhong)一(yi)個(ge)(ge)腳(jiao)的電壓(ya)稍高(gao),那(nei)么(me)此腳(jiao)為三(san)極管(guan)(guan)(guan)的發射(she)極E,剩下的電壓(ya)偏低的那(nei)個(ge)(ge)管(guan)(guan)(guan)腳(jiao)為集(ji)電極C。
(2)如果三極管的(de)(de)紅表(biao)筆(bi)接(jie)(jie)其(qi)(qi)中一個管(guan)(guan)(guan)腳(jiao)(jiao),而用黑表(biao)筆(bi)測其(qi)(qi)它兩個管(guan)(guan)(guan)腳(jiao)(jiao)都導通有電壓(ya)(ya)顯示,那(nei)(nei)么此(ci)三極(ji)管(guan)(guan)(guan)為NPN三極(ji)管(guan)(guan)(guan),且紅表(biao)筆(bi)所(suo)接(jie)(jie)的(de)(de)腳(jiao)(jiao)為三極(ji)管(guan)(guan)(guan)的(de)(de)基極(ji)B,用上述方法測試時其(qi)(qi)中萬(wan)用表(biao)的(de)(de)黑表(biao)筆(bi)接(jie)(jie)其(qi)(qi)中一個腳(jiao)(jiao)的(de)(de)電壓(ya)(ya)稍高,那(nei)(nei)么此(ci)腳(jiao)(jiao)為三極(ji)管(guan)(guan)(guan)的(de)(de)發射極(ji)E,剩下的(de)(de)電壓(ya)(ya)偏低的(de)(de)那(nei)(nei)個管(guan)(guan)(guan)腳(jiao)(jiao)為集電極(ji)C。
2、hFE擋來進行判斷
在確(que)定了三(san)極管(guan)的(de)(de)(de)(de)基極和(he)(he)(he)管(guan)型后,將三(san)極管(guan)的(de)(de)(de)(de)基極按照(zhao)基極的(de)(de)(de)(de)位(wei)(wei)置(zhi)和(he)(he)(he)管(guan)型插入到(dao)盧(lu)值(zhi)測(ce)(ce)量(liang)孔中(zhong),其他兩個(ge)引腳插入到(dao)余下的(de)(de)(de)(de)三(san)個(ge)測(ce)(ce)量(liang)孔中(zhong)的(de)(de)(de)(de)任意兩個(ge),觀(guan)察顯(xian)(xian)示屏上數據的(de)(de)(de)(de)大小,找出三(san)極管(guan)的(de)(de)(de)(de)集電極和(he)(he)(he)發射極,交(jiao)換位(wei)(wei)置(zhi)后再(zai)測(ce)(ce)量(liang)一(yi)(yi)下,觀(guan)察顯(xian)(xian)示屏數值(zhi)的(de)(de)(de)(de)大小,反復測(ce)(ce)量(liang)四次,對比觀(guan)察。以所測(ce)(ce)的(de)(de)(de)(de)數值(zhi)最大的(de)(de)(de)(de)一(yi)(yi)次為準,就是三(san)極管(guan)的(de)(de)(de)(de)電流放大系(xi)數盧(lu),相對應插孔的(de)(de)(de)(de)電極即是三(san)極管(guan)的(de)(de)(de)(de)集電極和(he)(he)(he)發射極。
二、三極管測判口訣有哪些
口訣(jue)是(shi)一種以(yi)簡化字詞(ci),追(zhui)求順口易(yi)懂的記憶方式,電路(lu)板也(ye)有口訣(jue)!
三極(ji)管類型判(pan)斷及(ji)引腳判(pan)別屬于電子基(ji)礎,一般電工技術(shu)初學者都會(hui)接觸到,而苦澀(se)難記的專業名詞不(bu)利于初學者記憶,如果(guo)你(ni)懂得:“三顛倒,找基(ji)極(ji)、PN結,定(ding)管型、順箭(jian)頭(tou),偏轉大(da)、測不(bu)準,動嘴巴。”或許就輕松(song)多(duo)了,當然,口訣背了卻(que)不(bu)知道意思,那也(ye)是(shi)沒用。
具體(ti)的口訣應用為:
1、口訣第一句:三顛倒,找基極。
大家知(zhi)道,三極管(guan)是含有兩(liang)個PN結(jie)的(de)半導體(ti)器件(并非(fei)單獨(du)的(de)兩(liang)個PN結(jie)串(chuan)聯(lian))。而根(gen)據兩(liang)個PN結(jie)連接(jie)方式(shi)不(bu)同,三極管(guan)可分(fen)為NPN型(xing)和PNP型(xing)。
三極(ji)(ji)管(guan)的(de)(de)測(ce)(ce)試(shi)是(shi)(shi)使用(yong)(yong)(yong)的(de)(de)萬(wan)用(yong)(yong)(yong)電(dian)表(biao)(biao)的(de)(de)歐姆擋(dang)R×100或R×1k擋(dang)位。而指針(zhen)式萬(wan)用(yong)(yong)(yong)電(dian)表(biao)(biao),紅筆為(wei)(wei)萬(wan)用(yong)(yong)(yong)表(biao)(biao)負極(ji)(ji),黑(hei)筆為(wei)(wei)萬(wan)用(yong)(yong)(yong)表(biao)(biao)電(dian)池(chi)正(zheng)極(ji)(ji)。在測(ce)(ce)試(shi)三極(ji)(ji)管(guan)管(guan)型時,第一(yi)(yi)(yi)步(bu)要(yao)先判斷引腳(jiao)(jiao)的(de)(de)基(ji)極(ji)(ji)位置。測(ce)(ce)量(liang)(liang)方法(fa):隨意選取兩(liang)(liang)個(ge)(ge)電(dian)極(ji)(ji)(如這(zhe)兩(liang)(liang)個(ge)(ge)電(dian)極(ji)(ji)為(wei)(wei)1、2),首先測(ce)(ce)量(liang)(liang)正(zheng)反電(dian)阻(zu),觀(guan)察(cha)表(biao)(biao)針(zhen)的(de)(de)偏(pian)轉角(jiao)度(du)(du);接(jie)著,再取1、3兩(liang)(liang)個(ge)(ge)電(dian)極(ji)(ji)和2、3兩(liang)(liang)個(ge)(ge)電(dian)極(ji)(ji),分別顛倒(dao)測(ce)(ce)量(liang)(liang)它們的(de)(de)正(zheng)、反向電(dian)阻(zu),觀(guan)察(cha)表(biao)(biao)針(zhen)的(de)(de)偏(pian)轉角(jiao)度(du)(du)。在這(zhe)三次(ci)(ci)顛倒(dao)測(ce)(ce)量(liang)(liang)中,必(bi)然有兩(liang)(liang)次(ci)(ci)測(ce)(ce)量(liang)(liang)結果(guo)相近(jin):即顛倒(dao)測(ce)(ce)量(liang)(liang)中表(biao)(biao)針(zhen)一(yi)(yi)(yi)次(ci)(ci)偏(pian)轉大,一(yi)(yi)(yi)次(ci)(ci)偏(pian)轉小;剩(sheng)下一(yi)(yi)(yi)次(ci)(ci)必(bi)然是(shi)(shi)顛倒(dao)測(ce)(ce)量(liang)(liang)前后指針(zhen)偏(pian)轉角(jiao)度(du)(du)都很小,這(zhe)一(yi)(yi)(yi)次(ci)(ci)未測(ce)(ce)的(de)(de)那只管(guan)腳(jiao)(jiao)就是(shi)(shi)我(wo)們要(yao)尋找的(de)(de)基(ji)極(ji)(ji)。
2、口訣第二句:PN結,找管型
經過(guo)上(shang)訴測(ce)量,我們確定引腳(jiao)基極之后,就可以根據基極與另外兩個電(dian)極之間PN結方向(xiang)來確定管(guan)(guan)型。測(ce)量方法:將萬用表的黑表筆置(zhi)于基極,紅(hong)表筆置(zhi)于其余任一(yi)電(dian)極,若表頭指針(zhen)偏轉角度很(hen)大,則說明(ming)被(bei)測(ce)三極管(guan)(guan)為NPN型管(guan)(guan);若表頭指針(zhen)偏轉角度很(hen)小,則被(bei)測(ce)管(guan)(guan)即為PNP型。
3、口訣第三句:順箭頭,偏轉大
NPN型(xing)三(san)(san)極(ji)管(guan)(guan):根據NPN型(xing)三(san)(san)極(ji)管(guan)(guan)穿透(tou)電(dian)流(liu)(liu)(liu)的(de)(de)流(liu)(liu)(liu)向原(yuan)理,用(yong)萬(wan)用(yong)電(dian)表(biao)的(de)(de)黑(hei)、紅表(biao)筆顛倒測量兩極(ji)間的(de)(de)正、反向電(dian)阻Rce和(he)Rec,獲取兩次測量結果,發(fa)現(xian)表(biao)頭指針偏(pian)轉均(jun)小(xiao),經過細心觀(guan)察(cha),會發(fa)現(xian)有(you)一次偏(pian)轉角度(du)偏(pian)大一點,即此次電(dian)流(liu)(liu)(liu)流(liu)(liu)(liu)向為:黑(hei)筆→c極(ji)→b極(ji)→e極(ji)→紅筆,流(liu)(liu)(liu)向吻合(he)三(san)(san)極(ji)管(guan)(guan)符號箭頭的(de)(de)流(liu)(liu)(liu)向,所(suo)(suo)以此時(shi)黑(hei)表(biao)筆所(suo)(suo)接(jie)(jie)的(de)(de)一定是集電(dian)極(ji)c,紅表(biao)筆所(suo)(suo)接(jie)(jie)的(de)(de)一定是發(fa)射(she)極(ji)e。
4、口訣第四句:表沒差,動嘴巴
在(zai)'第三(san)句口訣'的測(ce)量過程中(zhong),區分不出(chu)哪次偏轉指(zhi)針較大時(shi),那(nei)么,就要'動嘴巴'了。那(nei)么該如(ru)何(he)動嘴呢?進行第三(san)句口訣測(ce)量的時(shi)候,用(yong)兩只手(shou)分別捏(nie)住紅黑筆與管腳的結(jie)合部,接(jie)下去(qu)用(yong)嘴巴含住(舌頭碰觸也行)基電(dian)極(ji)b,然后對比兩次結(jie)果。由于(yu)人體起(qi)到直流偏置電(dian)阻的作(zuo)用(yong),所以兩次對比就會變得更加明顯。