一、避雷器與被保護設備并聯連接對嗎
對。
避(bi)雷(lei)器(qi)(qi)(qi)連接在線纜(lan)和大地(di)之間,通常與被保(bao)護(hu)設備并聯。避(bi)雷(lei)器(qi)(qi)(qi)用于保(bao)護(hu)交流輸變電(dian)(dian)設備的絕緣(yuan),免受雷(lei)電(dian)(dian)過電(dian)(dian)壓(ya)和操(cao)作過電(dian)(dian)壓(ya)損害。避(bi)雷(lei)器(qi)(qi)(qi)適用于變壓(ya)器(qi)(qi)(qi)、輸電(dian)(dian)線路(lu)、配電(dian)(dian)屏、開(kai)關(guan)柜(ju)、電(dian)(dian)力計(ji)量箱(xiang)、真空開(kai)關(guan)、并聯補(bu)償電(dian)(dian)容器(qi)(qi)(qi)、旋轉電(dian)(dian)機及半導(dao)體器(qi)(qi)(qi)件等過電(dian)(dian)壓(ya)保(bao)護(hu)。
二、避雷器放電計數器測試儀的功能特點
1、使(shi)用(yong)前請(qing)先充電(dian)(dian)(dian)(dian),為確保充電(dian)(dian)(dian)(dian)效(xiao)果和延長電(dian)(dian)(dian)(dian)池使(shi)用(yong)壽命,需使(shi)用(yong)專配的充電(dian)(dian)(dian)(dian)器(qi)。空電(dian)(dian)(dian)(dian)池到充滿約(yue)需3-4小時,充電(dian)(dian)(dian)(dian)器(qi)上(shang)紅燈亮(liang)表(biao)示正在充電(dian)(dian)(dian)(dian)。
2、根據計數器安裝高(gao)度,適當拉出伸縮放電桿。
3、專(zhuan)配(pei)的接地線,一(yi)端插(cha)頭插(cha)入校驗器尾部插(cha)孔,另一(yi)端夾(jia)子(zi)接大地。
4、按(an)下紅色按(an)鈕,接通高壓約1秒鐘,指示燈(deng)亮起(微(wei)閃),即(ji)可輕輕點擊計數(shu)器(qi)與避雷(lei)器(qi)的連接端進(jin)行測試。
5、每次點擊后(hou),放(fang)電桿端頭應離開計數器。若需重復測(ce)試(shi),不要松開按鈕,待1-2秒指示(shi)燈又閃爍(shuo)時,即可再次點擊測(ce)試(shi)。
6、連續(xu)測試會(hui)導致校(xiao)驗儀發熱,請(qing)注(zhu)意適(shi)當間隙(xi)時間。以(yi)減少故障,延長電池壽命。
7、校驗(yan)器(qi)輸出分高、中、低三(san)檔,可通過(guo)頭部的撥動(dong)開關進行(xing)調節,以適(shi)應測試不同(tong)類型或廠(chang)牌(pai)的計數器(qi)。
8、如按下按鈕3秒鐘以上指示燈仍未閃(shan)亮(liang),則表示需(xu)要(yao)對(dui)電(dian)池進行充電(dian)。
9、校驗器請(qing)勿隨意(yi)拆卸。
三、避雷器電氣符號及含義
避(bi)雷(lei)(lei)器(qi)電(dian)(dian)氣(qi)符(fu)號是電(dian)(dian)氣(qi)圖中用(yong)于表示避(bi)雷(lei)(lei)器(qi)的專(zhuan)用(yong)符(fu)號。避(bi)雷(lei)(lei)器(qi)是一種用(yong)于保護電(dian)(dian)力設備及電(dian)(dian)氣(qi)系統(tong)的電(dian)(dian)氣(qi)裝置,主要用(yong)于解決(jue)雷(lei)(lei)電(dian)(dian)過(guo)電(dian)(dian)壓問題。常用(yong)的避(bi)雷(lei)(lei)器(qi)電(dian)(dian)氣(qi)符(fu)號包括(kuo):
1、閃絡型避雷器:表示為一個(ge)箭頭,箭頭上(shang)方有(you)一個(ge)彎曲的線條(tiao),代表電擊火花。
2、氣體放電型避雷器:表示(shi)為一(yi)個箭頭,箭頭上方有(you)一(yi)個帶帽子的球體,表示(shi)球形電極。
3、組合型避雷器:表(biao)示為兩個箭(jian)頭和(he)一(yi)個電(dian)(dian)抗器(qi),箭(jian)頭分別表(biao)示高壓(ya)側(ce)和(he)地側(ce),電(dian)(dian)抗器(qi)則表(biao)示電(dian)(dian)器(qi)故(gu)障時(shi)的電(dian)(dian)容。
四、避雷器的工作原理
避(bi)雷器(qi)(qi)的(de)(de)主要工作(zuo)原理是(shi)利用(yong)金屬氧化物電(dian)阻變化的(de)(de)特性來調節接地(di)電(dian)阻,以吸收足夠的(de)(de)過電(dian)壓能(neng)量來保護(hu)電(dian)氣(qi)設備。當系統(tong)的(de)(de)電(dian)壓升高到某個臨(lin)界值時,避(bi)雷器(qi)(qi)開始起作(zuo)用(yong),其內部的(de)(de)絕(jue)緣材料(liao)失效(xiao),使(shi)內部載流(liu)(liu)體(通常是(shi)氣(qi)體或液(ye)體)電(dian)離。這(zhe)樣,就形成了一個低(di)阻抗(kang)通路,使(shi)得(de)漏電(dian)流(liu)(liu)通過避(bi)雷器(qi)(qi)流(liu)(liu)到接地(di)點(dian),以消除過電(dian)壓。
更多避雷器的知識,可以點擊避雷器十大品牌進行查看哦。