【室(shi)內(nei)物(wu)理環境設(she)計】家(jia)居給(gei)排水(shui)系統設(she)計 家(jia)居出水(shui)入(ru)水(shui)有道
一、室內給排水概述
1.1室內給水
從(cong)建筑物(wu)(wu)內(nei)(nei)部(bu)(bu)結構來說,給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)包(bao)括生(sheng)活給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)、生(sheng)產給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)、中水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)、消防給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)、以及組合給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)。例如(ru)(ru)自(zi)動排氣閥就是(shi)屬于給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong)的(de)(de)。設有(you)(you)(you)(you)延時(shi)自(zi)閉閥的(de)(de)蹲式大便器(qi)的(de)(de)室內(nei)(nei)給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)系(xi)(xi)統(tong)(tong)(tong),如(ru)(ru)學校(xiao)、旅(lv)館、辦公樓等,如(ru)(ru)果在(zai)給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)管(guan)(guan)系(xi)(xi)統(tong)(tong)(tong)的(de)(de)最頂層設有(you)(you)(you)(you)自(zi)閉閥,最好(hao)在(zai)管(guan)(guan)系(xi)(xi)的(de)(de)最高點增(zeng)設自(zi)動排氣裝(zhuang)置。因為給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)用的(de)(de)延時(shi)自(zi)閉閥能(neng)很(hen)好(hao)地(di)控制水(shui)(shui)(shui)流,但(dan)卻(que)不能(neng)很(hen)好(hao)地(di)控制氣流。當系(xi)(xi)統(tong)(tong)(tong)停水(shui)(shui)(shui)時(shi),給(gei)(gei)(gei)(gei)水(shui)(shui)(shui)管(guan)(guan)內(nei)(nei)常積存有(you)(you)(you)(you)大量(liang)的(de)(de)空(kong)氣。系(xi)(xi)統(tong)(tong)(tong)恢(hui)復供水(shui)(shui)(shui)后,管(guan)(guan)系(xi)(xi)內(nei)(nei)空(kong)氣常會被水(shui)(shui)(shui)流壓(ya)(ya)(ya)縮(suo)至管(guan)(guan)系(xi)(xi)頂部(bu)(bu)而(er)形成一(yi)個壓(ya)(ya)(ya)縮(suo)空(kong)氣區。此時(shi)有(you)(you)(you)(you)人再按下延時(shi)自(zi)閉閥的(de)(de)按扭(niu)時(shi),則(ze)壓(ya)(ya)(ya)縮(suo)的(de)(de)空(kong)氣會伴隨著(zhu)水(shui)(shui)(shui)流噴薄而(er)出,常會將便器(qi)內(nei)(nei)的(de)(de)污(wu)物(wu)(wu)吹到地(di)面(mian)以上(shang),甚至濺到入(ru)廁者的(de)(de)衣物(wu)(wu)上(shang)。在(zai)管(guan)(guan)系(xi)(xi)的(de)(de)最高點設一(yi)個自(zi)動排氣閥則(ze)可有(you)(you)(you)(you)效地(di)解決這(zhe)一(yi)問題(ti)。
2.2室內排水
排水系(xi)(xi)統包括生活排水系(xi)(xi)統,工(gong)業廢水排水系(xi)(xi)統,以(yi)及屋面雨水排水系(xi)(xi)統。這些系(xi)(xi)統中包括了水質處理,水質、水溫、水壓保證及供水、配水、排水、通(tong)氣等眾多技術(shu)內(nei)(nei)涵。隨(sui)著社會的(de)進步(bu)和科學得到(dao)發(fa)(fa)展,室內(nei)(nei)給排水在(zai)不(bu)斷(duan)派生出各種新(xin)(xin)的(de)子系(xi)(xi)統,新(xin)(xin)技術(shu)、新(xin)(xin)材料(liao)日新(xin)(xin)月異地涌現(xian)。室內(nei)(nei)給排水已成(cheng)為我國現(xian)代(dai)化建設(she)中一(yi)支不(bu)可(ke)忽(hu)視的(de)力量,在(zai)生活中起著舉(ju)足輕(qing)重的(de)作用(yong)。對(dui)于廚房和廁(ce)所相(xiang)鄰(lin)的(de)住宅來(lai)說(shuo),如果廚、廁(ce)是單(dan)獨的(de)排水管(guan)系(xi)(xi)統,則在(zai)最底(di)層為兩系(xi)(xi)統作一(yi)個緊急排出聯(lian)通(tong)。從對(dui)目前我國居民的(de)生活習慣(guan)來(lai)說(shuo),下(xia)水管(guan)道發(fa)(fa)生堵塞現(xian)象(xiang)發(fa)(fa)生的(de)可(ke)能性非常大(da),也可(ke)以(yi)說(shuo)只是堵的(de)次(ci)數多與少的(de)問題。如果室內(nei)(nei)設(she)計人(ren)員對(dui)傳(chuan)統作法稍做改動,則可(ke)在(zai)很(hen)大(da)程度上方(fang)便用(yong)戶(hu)。
二、室內給水設計
2.1生活給水系統
建(jian)筑物內應盡量利用室外管網的(de)水(shui)壓(ya)直接供水(shui),當水(shui)壓(ya)不滿足要求(qiu)時(shi)設加壓(ya)裝置,生活水(shui)池及(ji)其泵房設在底層,屋頂設水(shui)箱(xiang),各配水(shui)點處的(de)靜水(shui)壓(ya)不宜(yi)大于(yu)0.45MPa,同(tong)時最高層(ceng)水(shui)壓不宜(yi)小于0.10MPa,水壓大于0.35MPa的人戶管,應設(she)減(jian)壓設(she)施,且為了利用外管網的水壓,以節省能(neng)耗,一般(ban)以外管網能(neng)滿(man)(man)足水壓要求的樓(lou)層為低壓區,空調冷(leng)卻塔(ta)的補(bu)水量(liang)一般(ban)均較生活用水量(liang)大得多,因此有條(tiao)件的宜將冷(leng)卻塔(ta)置于(yu)低壓區。市政壓力不能(neng)滿(man)(man)足要求的給(gei)水系統的BA設計小(xiao)區每棟單(dan)體均設有(you)水池(chi)、水箱、水泵(beng),由(you)于數(shu)量多(duo),如用傳統的管理(li)(li)方式務必造成人(ren)力、資源的浪費,給(gei)管理(li)(li)帶來很多(duo)不便(bian),一般設計中采(cai)用BA系統對各(ge)個水池、水箱、水泵的運行狀(zhuang)態、故障狀(zhuang)態等進(jin)行監視、控制。BA系統中(zhong)的自動(dong)抄表系統解決了人工抄表帶來的諸多不便,更(geng)好(hao)地為住戶(hu)服務。給(gei)水系統的BA設計主要是(shi)通過液(ye)位、壓力(li)、流量等訊號對加(jia)壓泵(beng)、水池、水箱運行狀態進(jin)行監視、控制(zhi)。
2.2熱水系統
住宅樓熱水(shui)由各自煤氣、太陽能、電熱水(shui)器提(ti)供(gong),公共(gong)建筑熱水(shui)由集中熱水(shui)供(gong)應系(xi)統提(ti)供(gong)。
(1)公共(gong)建筑加(jia)熱(re)(re)設備的選(xuan)擇:加(jia)熱(re)(re)設備是熱(re)(re)水(shui)供應系(xi)統的核心,對于熱(re)(re)源(yuan)充足(zu)的地區采(cai)用半即熱(re)(re)式汽水(shui)熱(re)(re)交換器(qi),它具有體積(ji)小(xiao),占地小(xiao),自(zi)控精(jing)確,浮動(dong)盤(pan)管,自(zi)動(dong)除垢,自(zi)動(dong)過冷,熱(re)(re)水(shui)出水(shui)快(kuai),防“軍(jun)團菌”產(chan)生(sheng)等優點。
(2)熱水系統的BA設計:熱水系統(tong)的BA設(she)計(ji)主要是通過壓力、溫(wen)度信號(hao)實現對熱(re)交換器、熱(re)水(shui)循環泵的(de)啟停、故障,熱(re)水(shui)溫(wen)度的(de)監視(shi)控制。
2.3給水支管的布置與敷設
給水供應系統沒有固定的(de)形式,設(she)(she)計時應根(gen)據用戶(hu)的(de)要求,結合(he)室(shi)外給水系統的(de)實(shi)際情況(kuang)經(jing)技術經(jing)濟比較或采用綜(zong)合(he)評判法確定供水方式。普通住(zhu)宅給水系統我(wo)們應本著節能、便于管(guan)理(li)的(de)原則來選(xuan)用設(she)(she)計方案。當一戶(hu)設(she)(she)有兩(liang)(liang)個或兩(liang)(liang)個以(yi)上衛生間,給水管(guan)道(dao)需穿越房間時,橫管(guan)最好設(she)(she)于樓板墊(dian)層中,樓板降(jiang)低7cm―l0cm,墊(dian)層采(cai)用渣(zha)或細石(shi)混凝土。當有采(cai)暖管道穿梁敷設(或貼樓板下安裝),給水橫管應與采暖管道并排安裝,管道應盡量布置于客廳、餐廳等部位,這些位置是住戶裝修的重點區域,便于住戶在裝修中合理方便的處理管道。給水支管宜敷設在樓(地)面的找(zhao)(zhao)平(ping)層或沿墻敷(fu)設(she)在管(guan)(guan)槽(cao)內,敷(fu)設(she)在找(zhao)(zhao)平(ping)層或管(guan)(guan)槽(cao)內的給(gei)水支管(guan)(guan)外徑不宜大于25mm。實際上,如果將接(jie)往兩個或兩個以上用水點(dian)給(gei)水支管(guan)串聯在一起,其支管(guan)外徑均會超過25mm。因此,為了滿足規范要求,給水(shui)(shui)支(zhi)管人戶(hu)后即接入分(fen)水(shui)(shui)器,分(fen)水(shui)(shui)器暗設于廚房(fang)或衛生間(jian)墻體內,通(tong)過(guo)分(fen)水(shui)(shui)器后接往各用水(shui)(shui)點,其支(zhi)管外徑(jing)均可控制在25mm以下。
三、排水設計
3.1廚房排水管道的設置
廚(chu)房(fang)(fang)洗滌池排(pai)水(shui)(shui)(shui)支管(guan)(guan)可(ke)直接(jie)在樓板上接(jie)人排(pai)水(shui)(shui)(shui)立管(guan)(guan)。而對于廚(chu)房(fang)(fang)是否(fou)設地(di)(di)漏,目前(qian)還存在較大爭議(yi),建議(yi)廚(chu)房(fang)(fang)內不設地(di)(di)漏:現(xian)代(dai)生活中廚(chu)房(fang)(fang)地(di)(di)面一般已很(hen)少用(yong)水(shui)(shui)(shui)沖洗,少量(liang)的濺水(shui)(shui)(shui)用(yong)抹(mo)布就可(ke)完成地(di)(di)面的清(qing)潔,廚(chu)房(fang)(fang)地(di)(di)漏由于長時(shi)間無(wu)水(shui)(shui)(shui)補充,水(shui)(shui)(shui)封內存水(shui)(shui)(shui)蒸發(fa)后臭氣反由地(di)(di)漏進(jin)入(ru)室內。同時(shi),取消(xiao)地(di)(di)漏還可(ke)避免地(di)(di)漏排(pai)水(shui)(shui)(shui)支管(guan)(guan)進(jin)入(ru)下層戶(hu)內空(kong)間。
3.2衛生間排水管道的設置
新設計的住宅應致力于取消伸(shen)入下層住戶空間的排水橫管,具體做法有:
(1)使衛生(sheng)間地板(ban)面下沉,管道敷設在填(tian)渣(zha)層中。
(2)使(shi)衛生(sheng)間地板面不下沉,而使(shi)用(yong)P形坐便器(qi)(后出口(kou)式(shi)),使(shi)得下水(shui)管(guan)在本層與立管(guan)銜接(jie)。地(di)漏采用側(ce)壁式(shi),洗(xi)臉盆、浴缸等(deng)排水(shui)管(guan)也在地(di)面(mian)以(yi)(yi)上敷設與立管(guan)銜接(jie)。這兩種做法均(jun)可以(yi)(yi)使(shi)下水(shui)管(guan)道(dao)每(mei)層水(shui)平(ping)分(fen)隔開,若需(xu)要檢(jian)修(xiu)可以(yi)(yi)獨戶(hu)進行,不影響鄰居。
(3)地(di)漏(lou)與存水(shui)彎(wan)的配(pei)合(he)問題,傳統鐘(zhong)罩式地(di)漏(lou)的水(shui)封容易(yi)揮發,常常造成(cheng)下水(shui)道異味和排(pai)水(shui)口溢出(chu)的液體(ti)進入室內,形(xing)成(cheng)室內污染(ran)。所以(yi)在(zai)給排(pai)水(shui)設計(ji)中(zhong),必須重視這個問題。
3.3污水系統
室內一般糞(fen)(fen)便(bian)(bian)污水和(he)其他廢水合流(liu),高層(ceng)建筑(zhu)的(de)生活污水立(li)管(guan)設(she)置專用通氣(qi)立(li)管(guan),糞(fen)(fen)便(bian)(bian)污水經室外化糞(fen)(fen)池處理(li)(li)后排入市(shi)政(zheng)排水管(guan)網,職(zhi)工食堂和(he)營業(ye)的(de)含油污水單獨(du)設(she)隔油處理(li)(li)。為改(gai)善底(di)層(ceng)排水條件,采用底(di)層(ceng)污水獨(du)立(li)出戶,地下(xia)室污水設(she)污水集水坑及潛污泵(beng),經提升后排至室外。為減少投資,方便(bian)(bian)管(guan)理(li)(li),除規(gui)模很大的(de)建筑(zhu)群或有關部門(men)提出明確的(de)要求需要做中(zhong)水設(she)計外,一般小規(gui)模的(de)中(zhong)水系統,由于(yu)管(guan)理(li)(li)等(deng)問題,運行情況都不太(tai)好。
3.4給排水管道的設計
給排水立管應盡量置于同一個位置,最好位于通風道附近,以便于住戶進行裝修包裹。在有條件時最好設置管道井,可以將水表設于其中以做到水表出戶。當一戶設有兩個或兩個以上衛生間,給水管道需要穿越房間時,橫管(管徑小于De25)最好設于樓(lou)板(ban)面找(zhao)平層中。
四、結語
室內(nei)給排(pai)水(shui)系統看似簡單,但它(ta)與居(ju)民(min)的(de)日(ri)常生(sheng)活息息相關。作為給排(pai)水(shui)設計人員,應本(ben)著技術、安(an)全、美觀、實用(yong)、經濟的(de)原(yuan)則,在實踐中努力創新,尋求(qiu)最佳的(de)給排(pai)水(shui)設計方案(an),適應住宅設計發展(zhan)的(de)新要求(qiu),滿足人民(min)群眾不斷提高的(de)物質文化和生(sheng)活要求(qiu)。
推(tui)薦閱讀(du):
【室內物理環境設計】房間隔音不好怎么辦 房間隔音裝修方法大全
【室內物理環境設計】家居保溫隔熱設計方案 6招教裝出節能保溫房
【室內物(wu)理(li)環境(jing)設計(ji)】家(jia)居電氣(qi)設計(ji) 家庭(ting)裝修電(dian)氣設(she)計經驗提(ti)前看
【室內物理環境設計】家(jia)居通風設計技巧(qiao) 家(jia)居(ju)空(kong)氣流(liu)通有妙(miao)招