一、電源板強制開機方法
1、在實際檢測中,建議在主電源輸出(chu)的各組電壓上均接(jie)上相(xiang)應的假負載,這樣(yang)即(ji)可以(yi)準(zhun)確地判斷抄(chao)主(zhu)電源的工作(zuo)狀態,還可以(yi)避免(mian)部分電源因十12V(或(huo)十5V)空載而不(bu)工作(zuo)這一(yi)情況襲出(chu)現。
2、強(qiang)制(zhi)開(kai)(kai)機(ji)(ji)(ji):在單獨檢修電(dian)(dian)(dian)源板時(shi)(shi),應先找到電(dian)(dian)(dian)源板上(shang)的開(kai)(kai)/關(guan)機(ji)(ji)(ji)控制(zhi)端(duan),通常(chang)標注為:0N/0FF、STB、P0W或PWR..0/F等(deng),然后通過一只1KΩ~2KΩ的電(dian)(dian)(dian)阻與十5VS(或十5VSB)端(duan)相(xiang)連,讓開(kai)(kai)關(guan)電(dian)(dian)(dian)源各電(dian)(dian)(dian)路全部(bu)進入工作(zuo)狀態。對于大(da)部(bu)分液知(zhi)晶彩電(dian)(dian)(dian)的電(dian)(dian)(dian)源而言,由(you)于彩用(yong)的是高電(dian)(dian)(dian)平開(kai)(kai)機(ji)(ji)(ji),道(dao)故(gu)彩用(yong)上(shang)述方法均(jun)能(neng)強(qiang)制(zhi)開(kai)(kai)機(ji)(ji)(ji),但有少數開(kai)(kai)關(guan)電(dian)(dian)(dian)源釆(bian)用(yong)低電(dian)(dian)(dian)平開(kai)(kai)機(ji)(ji)(ji)方式,這時(shi)(shi)用(yong)導線將(jiang)電(dian)(dian)(dian)源板上(shang)的開(kai)(kai)/關(guan)端(duan)地(di)短接即(ji)可。
二、電源板怎么量輸出和輸入
1、用指針式萬用表測量(liang)液(ye)晶(jing)電源板(ban)基本電壓。
(1)將轉換開(kai)關(guan)打到直流電壓檔(dang)DCV中10V檔(dang)位上。
(2)將紅色(se)表筆(bi)插入標有(you)“+”號的(de)(de)插孔,黑色(se)表筆(bi)插入標有(you)“-”(或com)號的(de)(de)插孔。
(3)將紅色(se)表(biao)筆(bi)接(jie)液晶(jing)電源板的5V接(jie)點(dian),黑色(se)表(biao)筆(bi)接(jie)液晶(jing)電源板的接(jie)地(di)點(dian)。
(4)觀察萬用表的(de)指針的(de)指示數(shu)值,然(ran)后讀(du)數(shu)。
2、用(yong)(yong)指針(zhen)式(shi)萬用(yong)(yong)表測量液晶電(dian)源板(ban)的12V輸出(chu)電(dian)壓。
(1)將(jiang)轉換開關打(da)到直流電(dian)壓檔DCV中20V檔位上。
(2)將(jiang)紅色表筆插入標(biao)有(you)“+”號的(de)插孔,黑色表筆插入標(biao)有(you)“-”(或com)號的(de)插孔。
(3)將紅色(se)(se)表筆接(jie)液(ye)晶(jing)電(dian)源板的(de)12V接(jie)點(dian)處,黑色(se)(se)表筆接(jie)液(ye)晶(jing)電(dian)源板的(de)接(jie)地(di)點(dian)處。
(4)觀察萬用表的指(zhi)針的指(zhi)示數值,然后讀數。