一、消防滅火系統有哪幾種
消防滅火(huo)(huo)系(xi)(xi)(xi)統類(lei)型一(yi)般(ban)分(fen)為:火(huo)(huo)災(zai)自動報(bao)警系(xi)(xi)(xi)統、氣體滅火(huo)(huo)系(xi)(xi)(xi)統、泡(pao)沫滅火(huo)(huo)系(xi)(xi)(xi)統、防排(pai)煙系(xi)(xi)(xi)統、消防栓系(xi)(xi)(xi)統、滅火(huo)(huo)器配置、自動噴水(shui)滅火(huo)(huo)系(xi)(xi)(xi)統、火(huo)(huo)災(zai)應(ying)急照明和疏散指(zhi)示標志。
這些消防滅火(huo)系統一般都(dou)用在住宅、配電室(shi)、樓梯間(jian)、走道(dao)、地下(xia)車(che)庫等建(jian)筑(zhu)物(wu),幾(ji)乎所(suo)有建(jian)筑(zhu)物(wu)都(dou)要安裝。
二、消防滅火系統工作原理是什么
1、自動報警系統的工作原理
火(huo)(huo)(huo)(huo)災(zai)(zai)自(zi)動(dong)(dong)報(bao)(bao)警(jing)(jing)(jing)(jing)系統應由觸(chu)發(fa)裝(zhuang)置(zhi)、災(zai)(zai)報(bao)(bao)警(jing)(jing)(jing)(jing)裝(zhuang)置(zhi)、災(zai)(zai)警(jing)(jing)(jing)(jing)報(bao)(bao)裝(zhuang)置(zhi)和(he)電源等四部分(fen)組成,火(huo)(huo)(huo)(huo)災(zai)(zai)報(bao)(bao)警(jing)(jing)(jing)(jing)大(da)致過程:當煙、溫(wen)度、光(guang)、氣體濃度等火(huo)(huo)(huo)(huo)場參數超過某一(yi)給定(ding)閾(yu)值(zhi)時,火(huo)(huo)(huo)(huo)災(zai)(zai)探測器動(dong)(dong)作(zuo),發(fa)出(chu)報(bao)(bao)警(jing)(jing)(jing)(jing)號(hao),該信(xin)號(hao)經過連接導線(xian)傳(chuan)送至區(qu)域火(huo)(huo)(huo)(huo)災(zai)(zai)報(bao)(bao)警(jing)(jing)(jing)(jing)控制器和(he)(或)集(ji)中火(huo)(huo)(huo)(huo)災(zai)(zai)報(bao)(bao)警(jing)(jing)(jing)(jing)控制器,發(fa)出(chu)聲、光(guang)報(bao)(bao)警(jing)(jing)(jing)(jing)信(xin)號(hao),同時顯示火(huo)(huo)(huo)(huo)災(zai)(zai)發(fa)生的部位,以通知消防值(zhi)班(ban)人(ren)員做出(chu)反應,這也(ye)就是我(wo)們通常所(suo)說(shuo)的火(huo)(huo)(huo)(huo)災(zai)(zai)自(zi)動(dong)(dong)報(bao)(bao)警(jing)(jing)(jing)(jing)系統的工作(zuo)原(yuan)理。
2、防排煙系統的工作原理
當發(fa)生災后(hou),操作(zuo)機(ji)構在(zai)煙(yan)感(gan)報(bao)警(jing)電信(xin)(xin)號作(zuo)用下,將風(feng)(feng)閥(fa)自動(dong)打開,并啟動(dong)送風(feng)(feng)機(ji)與(yu)排煙(yan)風(feng)(feng)機(ji),當排煙(yan)管內的氣流(liu)達到280°C時,管道防火閥(fa)熔斷器熔斷。關(guan)閉(bi)防火閥(fa),關(guan)閉(bi)信(xin)(xin)號通(tong)過輸(shu)入模塊發(fa)送至控(kong)制器,自動(dong)或手動(dong)啟動(dong)相(xiang)應控(kong)制模塊去(qu)關(guan)閉(bi)排煙(yan)機(ji)。
在有空(kong)調設備時(shi),空(kong)調送(song)(song)風管道內的(de)氣(qi)流溫度(du)達到70°C時(shi),防(fang)(fang)火熔斷器(qi)動(dong)(dong)作(zuo),關(guan)(guan)閉防(fang)(fang)火閥(fa),關(guan)(guan)閉信號通過輸入(ru)模塊(kuai)傳送(song)(song)至控制器(qi),控制器(qi)則(ze)根(gen)據聯動(dong)(dong)關(guan)(guan)系給(gei)控制模塊(kuai)信號,關(guan)(guan)閉空(kong)調機。
3、泡沫系統的工作原理
(1)閉式泡沫噴淋滅火系統工作原理
當有(you)火(huo)災發(fa)生時,閉式(shi)噴(pen)(pen)頭(tou)的(de)玻璃球破裂噴(pen)(pen)水(shui),水(shui)流指(zhi)示器、濕式(shi)報警閥(fa)動作,有(you)信號(hao)傳(chuan)至控制柜,此時,手動或自動開啟消防泵比例(li)(li)混(hun)合裝(zhuang)置上的(de)電磁閥(fa)及管路閥(fa)門,系統工作。一定壓(ya)力的(de)消防水(shui)經泡(pao)沫(mo)比例(li)(li)混(hun)合裝(zhuang)置與泡(pao)沫(mo)液混(hun)合,形成一定比例(li)(li)的(de)泡(pao)沫(mo)混(hun)合液,經噴(pen)(pen)頭(tou)生成空氣(qi)泡(pao)沫(mo)滅(mie)火(huo)。
系統組(zu)成(cheng):閉(bi)式泡沫噴淋(lin)滅火系統主(zhu)要由消防水泵泡沫比例混合裝置、閉(bi)式噴頭、水流指示器、濕式報警(jing)閥及其它閥門、管道(dao)等組(zu)成(cheng)。
(2)開式泡沫噴淋滅火系統的工作原理
當有(you)火災發生(sheng)時,安裝于(yu)保護(hu)區(qu)的火災探測器有(you)信(xin)號傳至控(kong)制柜(ju),此時,手(shou)動或自動開啟雨淋閥(fa)(fa)、消(xiao)防泵比(bi)例(li)混合(he)器上(shang)的電磁閥(fa)(fa)及管路閥(fa)(fa)門,系統工作。壓力消(xiao)防水經泡沫(mo)(mo)(mo)比(bi)例(li)混合(he)裝置與泡沫(mo)(mo)(mo)液混合(he),形(xing)成一定比(bi)例(li)的泡沫(mo)(mo)(mo)混合(he)液,經噴頭生(sheng)成空氣(qi)泡沫(mo)(mo)(mo)滅火。
系統(tong)組(zu)成:開(kai)式泡沫(mo)噴(pen)淋滅火系統(tong)主要(yao)由消防水泵、泡沫(mo)比例混(hun)合裝置、開(kai)式噴(pen)頭、雨淋閥(fa)及其它閥(fa)門、管道等組(zu)成。
4、室內外消火栓系統的工作原理
消(xiao)火栓開(kai)啟,有水(shui)噴出(chu),恒壓泵(beng)(beng)啟動,恒壓對管網補(bu)壓,按(an)下破玻按(an)鈕,消(xiao)防(fang)中心(xin)收到破玻按(an)鈕報警信(xin)號,警鈴鳴響,直接啟動主消(xiao)防(fang)水(shui)泵(beng)(beng),消(xiao)防(fang)水(shui)泵(beng)(beng)對管網進行加壓,消(xiao)火栓上(shang)的啟泵(beng)(beng)指示(shi)燈亮。消(xiao)防(fang)中心(xin)收到消(xiao)防(fang)水(shui)泵(beng)(beng)運行信(xin)號。
因水(shui)(shui)泵(beng)壞或水(shui)(shui)池無水(shui)(shui)時,消防車對水(shui)(shui)泵(beng)接合(he)器進行(xing)加壓,保(bao)證消防系統能正常(chang)運行(xing)。(水(shui)(shui)泵(beng)能手動啟動,消防中(zhong)心手動啟動、自動啟動)。
5、噴淋自動滅火系統的工作原理
噴淋(lin)頭達到(dao)額定溫(wen)度時,玻(bo)璃(li)內的液(ye)體(ti)發熱膨脹,玻(bo)璃(li)管破碎(sui),噴淋(lin)頭噴水,水流指示器(qi)報(bao)(bao)警(jing)(jing),消防中(zhong)(zhong)心(xin)(xin)收到(dao)報(bao)(bao)警(jing)(jing)信(xin)號(hao)(hao),力(li)下(xia)降,水池或恒壓(ya)(ya)泵(beng)補(bu)壓(ya)(ya),濕式報(bao)(bao)警(jing)(jing)閥動(dong)作,水力(li)警(jing)(jing)鐘鳴響,壓(ya)(ya)力(li)開關報(bao)(bao)警(jing)(jing),消防中(zhong)(zhong)心(xin)(xin)收報(bao)(bao)警(jing)(jing)信(xin)號(hao)(hao),水泵(beng)起泵(beng)加(jia)壓(ya)(ya)。消防中(zhong)(zhong)心(xin)(xin)收到(dao)噴淋(lin)泵(beng)運(yun)行(xing)信(xin)號(hao)(hao)。因(yin)水泵(beng)壞或水池無水時,消防車對水泵(beng)接合(he)器(qi)進行(xing)加(jia)壓(ya)(ya),保證消防系統(tong)能正(zheng)常(chang)運(yun)行(xing)。(水泵(beng)能手(shou)動(dong)啟(qi)動(dong),消防中(zhong)(zhong)心(xin)(xin)手(shou)動(dong)啟(qi)動(dong)、自(zi)動(dong)啟(qi)動(dong))。
6、氣體自動滅火系統的工作原理
感煙或(huo)感溫探(tan)測器任一報警(jing)(jing)(jing),主機收到(dao)信號,警(jing)(jing)(jing)鐘鳴(ming)響(xiang),感煙與感溫探(tan)測器同時(shi)報警(jing)(jing)(jing),主機收到(dao)信號,警(jing)(jing)(jing)鐘鳴(ming)響(xiang),光報警(jing)(jing)(jing)器鳴(ming)響(xiang)。30S后聯(lian)動(dong)(dong)風(feng)閥(fa)、停(ting)(ting)(ting)空(kong)調新(xin)風(feng)機等、啟動(dong)(dong)氣體進行滅火(huo)(因誤報時(shi)在30S內按(an)下(xia)門(men)(men)口或(huo)主機上的(de)急停(ting)(ting)(ting)按(an)鈕(niu)停(ting)(ting)(ting)止放氣)。人員發現火(huo)災時(shi),直接(jie)按(an)下(xia)門(men)(men)口或(huo)主機上的(de)緊急放氣按(an)鈕(niu),直接(jie)聯(lian)動(dong)(dong)風(feng)閥(fa)、停(ting)(ting)(ting)空(kong)調新(xin)風(feng)機等啟動(dong)(dong)氣體進行滅火(huo)。
因主機不能正常(chang)啟(qi)動(dong)氣體(ti)滅火時(shi),直(zhi)按(an)用機械啟(qi)動(dong)氣體(ti)進行(xing)滅火。
7、防火卷簾的工作原理
在(zai)火(huo)(huo)災發(fa)生時(shi)(shi)起(qi)防(fang)火(huo)(huo)分區隔斷作用,在(zai)火(huo)(huo)災發(fa)生時(shi)(shi),感(gan)煙探測器(qi)報警(jing),災信號送到(dao)(dao)(dao)卷(juan)簾(lian)(lian)門(men)(men)制柜,控制柜發(fa)出啟動信號,卷(juan)簾(lian)(lian)門(men)(men)自(zi)動降到(dao)(dao)(dao)距地1。8米的(de)位(wei)(wei)置(特殊(shu)部位(wei)(wei)的(de)卷(juan)簾(lian)(lian)門(men)(men)也可一步到(dao)(dao)(dao)底),如果感(gan)溫探測器(qi)再報警(jing),卷(juan)簾(lian)(lian)門(men)(men)才(cai)降到(dao)(dao)(dao)底。報警(jing)狀態時(shi)(shi),人(ren)員可手(shou)動按(an)住上行(xing)按(an)鈕升起(qi)卷(juan)簾(lian)(lian),人(ren)過(guo)去(qu)后放開按(an)鈕后防(fang)火(huo)(huo)門(men)(men)又自(zi)動下行(xing)。
8、消防廣播的工作原理
當(dang)火(huo)災(zai)發(fa)(fa)生時(shi),災(zai)區域/層(ceng)(如(ru)n層(ceng))的消(xiao)(xiao)防(fang)煙感(gan)溫感(gan)等(deng)(deng)探測(ce)器發(fa)(fa)出(chu)報警(jing)動(dong)作信號(hao),消(xiao)(xiao)防(fang)接收控制(zhi)盤(pan)、邏輯(ji)控制(zhi)等(deng)(deng)消(xiao)(xiao)防(fang)聯動(dong)裝(zhuang)置(zhi)自動(dong)(或手動(dong))啟動(dong),通過(guo)消(xiao)(xiao)防(fang)發(fa)(fa)送控制(zhi)盤(pan)發(fa)(fa)出(chu)驅動(dong)和切換控制(zhi)信號(hao)。
一路去啟動消(xiao)防廣(guang)播錄(lu)放盤(pan),該盤(pan)可(ke)選擇(ze)播音(yin)卡播音(yin)或話筒播音(yin)作為緊急廣(guang)播,并可(ke)自動錄(lu)音(yin)。
9、恒壓泵的工作原理
當管網泄漏、系統(tong)壓(ya)力(li)降(jiang)至設(she)定(ding)(ding)壓(ya)力(li)下(xia)限(xian)時,穩壓(ya)水(shui)泵自動(dong)啟動(dong),對管網進行補壓(ya),以供(gong)(gong)消(xiao)防(fang)供(gong)(gong)水(shui)系統(tong)保證(zheng)最不(bu)利點的消(xiao)防(fang)所需壓(ya)力(li),當系統(tong)壓(ya)力(li)達到設(she)定(ding)(ding)壓(ya)力(li)上限(xian)時穩泵停止(zhi)工作,每次壓(ya)力(li)下(xia)降(jiang)時,都(dou)重(zhong)復上述遠(yuan)行過程,以穩定(ding)(ding)消(xiao)防(fang)管網的壓(ya)力(li)。
消(xiao)防(fang)(fang)用水時(shi)(shi)(shi),穩(wen)壓(ya)(ya)(ya)泵(beng)(beng)持續運(yun)行阻懷(huai)壓(ya)(ya)(ya)力(li)(li)的(de)下(xia)降(jiang),當力(li)(li)降(jiang)到消(xiao)防(fang)(fang)主(zhu)(zhu)泵(beng)(beng)啟(qi)動(dong)壓(ya)(ya)(ya)力(li)(li)時(shi)(shi)(shi),電控系統發出報警信(xin)號,啟(qi)動(dong)消(xiao)防(fang)(fang)主(zhu)(zhu)泵(beng)(beng)進行供水,當消(xiao)防(fang)(fang)主(zhu)(zhu)泵(beng)(beng)運(yun)行到達額定流量種壓(ya)(ya)(ya)力(li)(li)時(shi)(shi)(shi),控制系統關閉(bi)主(zhu)(zhu)泵(beng)(beng)穩(wen)壓(ya)(ya)(ya)水運(yun)行,當單(dan)臺消(xiao)防(fang)(fang)泵(beng)(beng)運(yun)行機制信(xin)用證阻止不住壓(ya)(ya)(ya)力(li)(li)下(xia)降(jiang),系統壓(ya)(ya)(ya)力(li)(li)降(jiang)至消(xiao)防(fang)(fang)最低壓(ya)(ya)(ya)力(li)(li)時(shi)(shi)(shi),消(xiao)防(fang)(fang)備(bei)用泵(beng)(beng)啟(qi)動(dong)(有(you)兩主(zhu)(zhu)一備(bei)時(shi)(shi)(shi))。