變壓器簡介
變壓器是利用電磁感應的原理來改變交流電壓的裝置,主要構件是初級線圈、次級線圈和鐵心(磁芯)。在電器設備和無線電路中,常用作升降電壓、匹配阻抗,安全隔離等。變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)按用(yong)途可以分(fen)為配電變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、電力變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、全密(mi)封變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、組合式變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、干(gan)式變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、單相變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、電爐變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、整流變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、電抗(kang)器(qi)(qi)(qi)、抗(kang)干(gan)擾變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、防雷變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、箱式變(bian)(bian)電器(qi)(qi)(qi)、試(shi)驗變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、轉角(jiao)變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)、大電流變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)和勵磁變(bian)(bian)壓(ya)(ya)(ya)(ya)器(qi)(qi)(qi)。
變壓器的原理
利用電(dian)(dian)(dian)磁感應原理將(jiang)電(dian)(dian)(dian)能或電(dian)(dian)(dian)信號(hao)從一(yi)個電(dian)(dian)(dian)路傳遞到(dao)(dao)另(ling)一(yi)個電(dian)(dian)(dian)路的(de)(de)(de)靜止器(qi)(qi)(qi)件。電(dian)(dian)(dian)子電(dian)(dian)(dian)路中的(de)(de)(de)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)主要用于電(dian)(dian)(dian)壓(ya)(ya)(ya)幅度變(bian)(bian)換和電(dian)(dian)(dian)路負載的(de)(de)(de)阻(zu)抗匹配(pei)(pei)變(bian)(bian)換。它(ta)由繞在(zai)鐵芯上的(de)(de)(de)初級繞組(zu)(原組(zu))和次級繞組(zu)(副組(zu))組(zu)成(cheng)。工作電(dian)(dian)(dian)壓(ya)(ya)(ya)自毫伏級到(dao)(dao)千伏級;輸出(chu)功率(lv)從毫瓦級到(dao)(dao)千瓦級;工作頻率(lv)從幾十赫一(yi)直到(dao)(dao)射(she)頻;波(bo)(bo)形除正(zheng)弦波(bo)(bo)外,還有矩(ju)形波(bo)(bo)、脈(mo)沖波(bo)(bo)和各種(zhong)復雜的(de)(de)(de)波(bo)(bo)形。常用的(de)(de)(de)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)除一(yi)般(ban)的(de)(de)(de)電(dian)(dian)(dian)源變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)外,還有音頻變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)、阻(zu)抗匹配(pei)(pei)變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)、脈(mo)沖變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)、視頻變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)、射(she)頻變(bian)(bian)壓(ya)(ya)(ya)器(qi)(qi)(qi)等。
變壓器參數有哪些
對不同類型的(de)變(bian)(bian)壓(ya)(ya)器都有相應的(de)技(ji)述(shu)(shu)(shu)要(yao)求,可(ke)用相應的(de)技(ji)述(shu)(shu)(shu)參數表(biao)示。如電源變(bian)(bian)壓(ya)(ya)器的(de)主要(yao)技(ji)述(shu)(shu)(shu)參數有:額定(ding)功率(lv)、額定(ding)電壓(ya)(ya)和電壓(ya)(ya)比(bi)、額定(ding)頻(pin)(pin)率(lv)、工作(zuo)溫(wen)度等(deng)級(ji)、溫(wen)升、電壓(ya)(ya)調整率(lv)、絕緣(yuan)性能和防潮性能,對于一(yi)般低(di)頻(pin)(pin)變(bian)(bian)壓(ya)(ya)器的(de)主要(yao)技(ji)述(shu)(shu)(shu)參數是:變(bian)(bian)壓(ya)(ya)比(bi)、頻(pin)(pin)率(lv)特性、非線性失真、磁屏蔽和靜電屏蔽、效率(lv)等(deng)。
變壓器(qi)的主要參數(shu)有電壓比、頻率(lv)特(te)性、額定功率(lv)和效率(lv)等。
1、電壓比n
變壓器的電壓比n與一(yi)次、二次繞組的匝(za)數和電(dian)壓之間的關系如下:n=V1/V2=N1/N2式中N1為(wei)變壓器一次(初級)繞(rao)組(zu),N2為(wei)二次(ci)(ci)(次(ci)(ci)級)繞組,V1為一次繞組(zu)兩端的電(dian)壓,V2是二次繞組(zu)兩端的(de)(de)電壓。升(sheng)壓變壓器的(de)(de)電壓比n小于1,降(jiang)壓(ya)(ya)變(bian)壓(ya)(ya)器的電(dian)壓(ya)(ya)比(bi)n大于1,隔離變(bian)壓器的電(dian)壓比等(deng)于1。
2、額定功率P
此參數(shu)一般用于(yu)電(dian)(dian)源變(bian)壓(ya)(ya)器(qi)(qi)(qi)。它是指(zhi)電(dian)(dian)源變(bian)壓(ya)(ya)器(qi)(qi)(qi)在(zai)規定(ding)(ding)的(de)工作(zuo)頻率和電(dian)(dian)壓(ya)(ya)下,能長期工作(zuo)而不超過限(xian)定(ding)(ding)溫(wen)度時(shi)的(de)輸出功率。變(bian)壓(ya)(ya)器(qi)(qi)(qi)的(de)額(e)定(ding)(ding)功率與鐵心截(jie)面(mian)積、漆(qi)包(bao)線直徑(jing)(jing)等有關(guan)。變(bian)壓(ya)(ya)器(qi)(qi)(qi)的(de)鐵心截(jie)面(mian)積大、漆(qi)包(bao)線直徑(jing)(jing)粗,其輸出功率也大。
3、頻率特性
頻(pin)(pin)率(lv)特性是(shi)指變壓(ya)器(qi)有(you)一定有(you)工(gong)作頻(pin)(pin)率(lv)范圍(wei),不同工(gong)作頻(pin)(pin)率(lv)范圍(wei)的變壓(ya)器(qi),一般不能互(hu)換使用(yong)。因為變壓(ya)器(qi)有(you)其頻(pin)(pin)率(lv)范圍(wei)以外工(gong)作時,會出現工(gong)作時溫度升高(gao)或不能正(zheng)常工(gong)作等現象。
4、效率效率
是(shi)指在額定(ding)負載時,變(bian)壓(ya)器輸出(chu)功(gong)率與(yu)輸入功(gong)率的(de)比值。該值與(yu)變(bian)壓(ya)器的(de)輸出(chu)功(gong)率成正(zheng)比,即變(bian)壓(ya)器的(de)輸出(chu)功(gong)率越(yue)大,效率也(ye)越(yue)高;變(bian)壓(ya)器的(de)輸出(chu)功(gong)率越(yue)小,效率也(ye)越(yue)低。變(bian)壓(ya)器的(de)效率值一般(ban)在60%~100%之間(jian)。
在額(e)定功(gong)(gong)率(lv)時(shi),變壓(ya)(ya)器的(de)輸出(chu)功(gong)(gong)率(lv)和(he)輸入功(gong)(gong)率(lv)的(de)比值,叫做變壓(ya)(ya)器的(de)效率(lv),即
η=x100%
式中η為變壓器的效率;P1為輸入功率,P2為輸出(chu)功率。
當變(bian)壓器的輸(shu)出(chu)功率P2等于輸(shu)入(ru)功率(lv)P1時,效率η等于100%,變(bian)壓器(qi)(qi)將(jiang)不產生(sheng)任何損(sun)(sun)耗(hao)。但實際上這種(zhong)變(bian)壓器(qi)(qi)是沒有的(de)。變(bian)壓器(qi)(qi)傳(chuan)輸(shu)電能時總要產生(sheng)損(sun)(sun)耗(hao),這種(zhong)損(sun)(sun)耗(hao)主要有銅(tong)損(sun)(sun)和鐵損(sun)(sun)。
銅損(sun)是(shi)指變壓器線圈電(dian)阻(zu)所引起的損(sun)耗。當(dang)電(dian)流通過線圈電(dian)阻(zu)發熱時(shi),一部分電(dian)能就轉變為(wei)熱能而損(sun)耗。由(you)于(yu)線圈一般(ban)都由(you)帶絕緣的銅線纏繞(rao)而成,因此(ci)稱為(wei)銅損(sun)。
變(bian)壓(ya)器(qi)(qi)的鐵(tie)損(sun)(sun)包(bao)括兩個方面。一是磁(ci)(ci)滯(zhi)損(sun)(sun)耗(hao),當交(jiao)流(liu)電流(liu)通(tong)過變(bian)壓(ya)器(qi)(qi)時(shi),通(tong)過變(bian)壓(ya)器(qi)(qi)硅鋼片(pian)的磁(ci)(ci)力線其(qi)方向和(he)大小隨之(zhi)變(bian)化,使(shi)得硅鋼片(pian)內部(bu)分子相互摩擦,放出熱能(neng),從(cong)而損(sun)(sun)耗(hao)了一部(bu)分電能(neng),這便(bian)是磁(ci)(ci)滯(zhi)損(sun)(sun)耗(hao)。另一是渦(wo)流(liu)損(sun)(sun)耗(hao),當變(bian)壓(ya)器(qi)(qi)工作時(shi)。鐵(tie)芯中有磁(ci)(ci)力線穿過,在與磁(ci)(ci)力線垂直的平面上就會產(chan)生感應電流(liu),由于此電流(liu)自(zi)成(cheng)(cheng)閉合回路形成(cheng)(cheng)環流(liu),且成(cheng)(cheng)旋渦(wo)狀,故稱(cheng)為渦(wo)流(liu)。渦(wo)流(liu)的存在使(shi)鐵(tie)芯發(fa)熱,消耗(hao)能(neng)量,這種(zhong)損(sun)(sun)耗(hao)稱(cheng)為渦(wo)流(liu)損(sun)(sun)耗(hao)。
變壓器(qi)的效(xiao)(xiao)率(lv)與(yu)變壓器(qi)的功(gong)率(lv)等級(ji)有(you)密(mi)切關系,通常功(gong)率(lv)越大,損耗(hao)與(yu)輸出(chu)功(gong)率(lv)就(jiu)越小,效(xiao)(xiao)率(lv)也就(jiu)越高。反之,功(gong)率(lv)越小,效(xiao)(xiao)率(lv)也就(jiu)越低。
如何從銘牌看參數
變壓(ya)器(qi)在規(gui)定(ding)的使(shi)用環境和(he)運行條(tiao)件(jian)下(xia),主要技術(shu)數據(ju)一般都(dou)都(dou)標(biao)注在變壓(ya)器(qi)的銘牌上。主要包(bao)括:額(e)定(ding)容量、額(e)定(ding)電(dian)壓(ya)及其分接、額(e)定(ding)頻率、繞組聯結組以及額(e)定(ding)性能數據(ju)(阻抗電(dian)壓(ya)、空(kong)載電(dian)流、空(kong)載損耗(hao)和(he)負(fu)載損耗(hao))和(he)總(zong)重。
A、額定容量(kVA):額(e)定電壓。額(e)定電流下連續運(yun)行時(shi),能輸送的容量(liang)。
B、額(e)定(ding)電壓(kV):變(bian)壓器長時間運行時所能承(cheng)受的(de)工作電(dian)壓。為適應電(dian)網電(dian)壓變(bian)化的(de)需要,變(bian)壓器高(gao)壓側(ce)都有分接抽頭,通過(guo)調(diao)整高(gao)壓繞組匝(za)數來調(diao)節低壓側(ce)輸出電(dian)壓。
C、額定電(dian)流(A):變壓器在額定容量下,允許長期通過(guo)的(de)電流。
D、空載損耗(hao)(kW):當以額定頻(pin)率(lv)的(de)額定電壓施加在一個繞(rao)組的(de)端子上,其(qi)余繞(rao)組開路時所吸取的(de)有功(gong)功(gong)率(lv)。與鐵心硅鋼片性能及(ji)制造工藝、和施加的(de)電壓有關(guan)。
E、空載電(dian)流(%):當變壓器在(zai)額定電壓下二(er)次側空載時,一次繞組中通過的電流。一般以額定電流的百分數表示。
F、負載損(sun)耗(kW):把變(bian)壓器的二次繞組短路,在一次繞組額定(ding)分接位置(zhi)上(shang)通入額定(ding)電流(liu),此時變(bian)壓器所消耗的功(gong)率。
G、阻抗電壓(ya)(%):把變壓器的(de)(de)(de)二(er)次(ci)繞(rao)(rao)組短(duan)路,在一(yi)次(ci)繞(rao)(rao)組慢慢升高電(dian)壓,當二(er)次(ci)繞(rao)(rao)組的(de)(de)(de)短(duan)路電(dian)流等于額定(ding)值時,此時一(yi)次(ci)側所(suo)施加(jia)的(de)(de)(de)電(dian)壓。一(yi)般以額定(ding)電(dian)壓的(de)(de)(de)百分數(shu)表示。
H、相(xiang)數(shu)和頻率:三(san)相(xiang)開頭以S表示,單相開(kai)頭(tou)以D表示。中(zhong)國(guo)國(guo)家(jia)標準頻率f為50Hz。國(guo)外有60Hz的國家(如美(mei)國)。
I、溫(wen)(wen)升(sheng)與(yu)冷卻:變壓(ya)器繞(rao)組或上層油(you)溫(wen)(wen)與(yu)變壓(ya)器周圍環境的溫(wen)(wen)度之(zhi)差,稱為(wei)繞(rao)組或上層油(you)面(mian)的溫(wen)(wen)升(sheng)。油(you)浸式變壓(ya)器繞(rao)組溫(wen)(wen)升(sheng)限值為(wei)65K、油(you)面溫升(sheng)為(wei)55K。冷(leng)(leng)卻方式也有多種(zhong):油浸自冷(leng)(leng)、強(qiang)迫風(feng)冷(leng)(leng),水冷(leng)(leng),管式、片式等。
J、絕(jue)緣(yuan)水平:有絕(jue)緣(yuan)等級標(biao)準。絕(jue)緣(yuan)水平的表示(shi)方法舉例如下:高壓額定電壓為35kV級,低壓額定電壓為(wei)10kV級(ji)的變壓器絕(jue)緣水(shui)平表(biao)示為(wei)LI200AC85/LI75AC35,其中LI200表示該變壓器高壓雷電(dian)沖擊耐(nai)受電(dian)壓為200kV,工(gong)頻耐(nai)受電壓為(wei)85kV,低壓雷電沖擊耐受電壓為75kV,工頻耐受(shou)電壓為35kV.
K、聯結(jie)組(zu)標(biao)號:根據變(bian)壓器一(yi)。二次繞(rao)(rao)組(zu)的(de)相(xiang)位關系(xi),把變(bian)壓器繞(rao)(rao)組(zu)連接成(cheng)各種不同的(de)組(zu)合,稱為(wei)繞(rao)(rao)組(zu)的(de)聯結(jie)組(zu)。為(wei)了(le)區別不同的(de)聯結(jie)組(zu),常采用(yong)時(shi)鐘表示法,即把高壓側(ce)線電壓的(de)相(xiang)量(liang)作為(wei)時(shi)鐘的(de)長針(zhen),固定在12上,低(di)壓側(ce)線(xian)電壓的相量作為(wei)時鐘的短(duan)針(zhen)(zhen),看(kan)短(duan)針(zhen)(zhen)指在哪(na)一個數字上,就作為(wei)該(gai)聯(lian)結(jie)組的標(biao)號。如Dyn11表(biao)示一次繞組(zu)是(shi)(三角形)聯結,二次繞組(zu)是(shi)帶(dai)有(you)中心點的(de)(星形)聯結,組(zu)號為(11)點。